Caution:
Monozone�
Ozone Generators produce high
quality ozone without oxides and
nitrogen as is produced in
Corona Discharge type of Ozone
Generator.
Monozone�
Ozone Generators are intended
for use in scientific research
and industrial and commercial
ozonation applications and
are not intended for use in
occupied areas. (The Food
and Drug Administration
prohibits any device that
generates or causes an
accumulation of more than 0.05
P.P.M. of ozone in the
atmosphere of an enclosed space
intended to be occupied by
people for extended periods of
time.)
Before performing maintenance on
your Monozone�
Ozone Generator, be sure to
unplug the unit from the wall
socket to prevent unnecessary
exposure to ultraviolet rays or
hazard of electrical shock.
Even short exposure to direct or
strongly reflected ultraviolet
germicidal rays will cause
painful eye irritation and
reddening of the skin. Personnel
subject to such exposure must
wear suitable face shield,
gloves and clothing.
MAINTENANCE:
A regular cycle of cleaning the
lamp and filter should be
established based on visual
inspection and experience. The
frequency of cleaning will vary
with the conditions surrounding
each installation. However, we
recommend that the lamp and air
filter be cleaned at least once
every three months.
Frequent cleanings will
insure:
1. Maximum germicidal
efficiency.
2. Continued, efficient
filtration performance as a
result of maximum electrostatic
effect.
3. Continued treatment of rated
air capacity as a result of low
filter resistance.
TO CLEAN FILTER:
The filter provided with your Monozone�
Ozone Generator is a permanent,
washable, electrostatic filter.
In most applications, regular
vacuuming will maintain peak
performance. Merely vacuum the
upstream sides first, then
repeat on the discharge side.
Periodically, a thorough flush
with clean water is recommended
to release any dirt not removed
by vacuuming. It is not
necessary to dry the filter
before returning to service -
merely shake off the excess
water and it is ready for use.
When heavy grease concentrations
are encountered, it is advisable
to wash the filter with a
detergent solution to allow the
grease concentration to be
dissolved. The detergent
solution should then be rinsed
thoroughly before the filter is
returned to service. Filters may
be cleaned repeatedly without
physical deterioration or loss
of efficiency.
TO CLEAN OZONE ULTRAVIOLET
LAMP:
The ozone ultraviolet lamps used
in your Monozone�
Ozone Generator, are premium
high output instant start lamps
with 10,000-rated effective
life. For best results, it is
recommended that lamps be
replaced after 10,000 hours
operation.
Lamps should be cleaned
periodically with clean rag and
water or alcohol as even a
slight film or layer of dust
will significantly reduce their
ability to produce ozone.
Inspect carefully to insure that
glass is thoroughly cleaned. It
is recommended that lamps be
cleaned each time the filter
maintenance is performed.
Finally remove any visible dust
from the interior of the Ozone
Generator with a vacuum cleaner
or soft clean cloth. If you have
any questions regarding
installation, operation or
maintenance, please contact the
factory. |
|