Ster-L-Ray�
Ultraviolet Germicidal Lamp |
|
|
Ster-L-Ray�
Slimline Germicidal Ultraviolet
Lamps
STER-L-RAY� Slimline germicidal
ultraviolet lamps are instant
starting and utilize a coil
filament on each end which
operates hot. Lamp life is
governed by the life of the
electrodes and is affected by
the frequency of starting.
STER-L-RAY� Slimline
germicidal ultraviolet lamps are
well suited to applications
requiring high ultraviolet
intensity such as water
sterilization, air purification
in duct systems and conveyorized
product disinfection. Available
in ozone producing and non-ozone
producing versions. |
|
Lamp
Description |
Length
(mm) Base Face
to Base Face |
Lamp
Watts
1 |
Approx Lamp
Current
mA |
Ultraviolet Output |
Ozone
Output if applicable
4 |
Rated Effect.
Life (hrs) |
Ozone
Free |
Ozone
Producing |
Total
Watts
2 |
Microwatts
@
1 meter
3 |
G12T5L |
G12T5VH |
233 |
11 |
425 |
3.1 |
32 |
0.8 |
10,000 |
G10T51/2L |
G10T51/2VH |
357 |
17 |
425 |
5.7 |
57 |
1.4 |
10,000 |
G18T5L |
G18T5VH |
386 |
18.4 |
425 |
5.8 |
59 |
1.6 |
10,000 |
G24T5L |
G24T5VH |
538 |
25.6 |
425 |
8.5 |
82 |
2.3 |
10,000 |
G30T5L |
G30T5VH |
691 |
32 |
425 |
11 |
95 |
3.0 |
10,000 |
GSL692T5L |
----- |
692 |
32 |
425 |
11 |
95 |
----- |
10,000 |
G36T5L* |
G36T5VH* |
843 |
41 |
425 |
15 |
130 |
3.7 |
10,000 |
G37T5L |
G37T5VH |
868 |
42 |
425 |
15.4 |
133 |
3.8 |
10,000 |
G48T5L |
G48T5VH |
1148 |
55 |
425 |
21 |
170 |
5.2 |
10,000 |
G64T5L* |
G64T5VH* |
1554 |
75 |
425 |
33 |
220 |
7.2 |
10,000 |
* Also
available in 2, 3 and 4-pin configurations
Custom lamp lengths can also be supplied
1
Wattage is lamp watts only and does not include ballast
loss.
2
Ultraviolet output at 254 nanometers at 100 hours and 80�F
(approximate).
3
Microwatts per square centimeter at one meter from lamp.
4 Approximate ozone output in grams per hour under favorable conditions. Figures apply
only to ozone producing types. Please note that ozone output is subject to considerable
variation due to conditions under which the lamp is used; under
many conditions, the ozone output may be only a fraction of the specified figure.
---
Please note that ozone output is subject to considerable variation due
to conditions under which the lamp is used; under many conditions, the
ozone output may be only a fraction of the specified figure.
Custom lamp lengths can also be supplied.
Hg - LAMP CONTAINS
MERCURY, manage in
accord with disposal
laws, see:
www.lamprecycle.org |
|
|
Ster-L-Ray�
is a
registered trademark of the
Atlantic Ultraviolet
Corp. |
|
|
|