Ster-L-Ray�
Ultraviolet Germicidal Lamp |
|
|
Ster-L-Ray�
Preheat
Germicidal Ultraviolet Lamps
STER-L-RAY� Preheat
germicidal lamps are
operated by a preheat
start circuit that
employs a relatively
compact and economical
ballast. The preheat
circuit requires four
electrical connections
per lamp and a slight to
moderate delay is needed
to start the lamp. Some
modern electronic
ballasts are capable of
instant starting a
preheat lamp. Available
in ozone producing and
non-ozone producing
versions. |
|
Lamp
Description |
Length
(mm)Base Face to Bace Face |
Lamp
Watts 1 |
Approx
Lamp
Current mA |
Ultraviolet Output |
Ozone
Output
If Applicable
4 |
Rated Effective
Life (hrs) |
Ozone
Free |
Ozone
Producing |
Total
Watts 2 |
Microwatts
@ 1 meter 3 |
GPH212T5L** |
GPH212T5VH** |
212 |
10 |
425 |
2.7 |
26 |
0.6 |
10,000 |
GPH238T5L/4 |
GPH238T5VH/4 |
238 |
11 |
425 |
3.0 |
30 |
0.65 |
10,000 |
GPH250T5L/4 |
GPH250T5VH/4 |
250 |
12 |
425 |
3.2 |
32 |
0.7 |
10,000 |
GPH254T5L/4 |
GPH254T5VH/4 |
254 |
12 |
425 |
3.3 |
33 |
0.71 |
10,000 |
GPH275T5L/4 |
GPH275T5VH/4 |
275 |
13 |
425 |
3.5 |
35 |
0.76 |
10,000 |
GPH287T5L** |
GPH287T5VH** |
287 |
14 |
425 |
4.0 |
40 |
0.9 |
10,000 |
GPH303T5L** |
GPH303T5VH** |
303 |
15 |
425 |
4.3 |
43 |
0.94 |
10,000 |
GPH330T5L/4 |
GPH330T5VH/4 |
330 |
16 |
425 |
4.6 |
46 |
1.0 |
10,000 |
GPH357T5L** |
GPH357T5VH** |
357 |
17 |
425 |
5.7 |
58 |
1.25 |
10,000 |
GPH436T5L** |
GPH436T5VH** |
436 |
21 |
425 |
7.3 |
72 |
1.6 |
10,000 |
GPH450T5L/4 |
GPH450T5L/4 |
450 |
22 |
425 |
7.5 |
75 |
1.6 |
10,000 |
GPH463T5L** |
GPH463T5L** |
463 |
23 |
425 |
8.0 |
78 |
1.7 |
10,000 |
GPH620T5L/4 |
GPH620T5VH/4 |
620 |
30 |
425 |
10.4 |
104 |
2.2 |
10,000 |
GPH650T5L/4 |
GPH650T5VH/4 |
650 |
34 |
425 |
11.0 |
109 |
2.4 |
10,000 |
GPH793T5L** |
GPH793T5VH** |
793 |
38 |
425 |
13.5 |
125 |
2.9 |
10,000 |
GPH810T5L/4 |
GPH810T5VH/4 |
810 |
39 |
425 |
13.8 |
130 |
3.0 |
10,000 |
GPH843T5L** |
GPH843T5VH** |
843 |
41 |
425 |
15.0 |
136 |
3.3 |
10,000 |
** Also available in 4-pin configuration.
Custom lamp lengths can also be supplied.
1
Wattage is lamp watts only and does not include ballast
loss.
2
Ultraviolet output at 254 nanometers at 100 hours and 80�F
(approximate).
3
Microwatts per square centimeter at one meter from lamp.
4 Approximate ozone output in grams per hour under favorable conditions. Figures apply
only to ozone producing types. Please note that ozone output is subject to considerable
variation due to conditions under which the lamp is used; under
many conditions, the ozone output may be only a fraction of the specified figure.
---
Please note that ozone output is subject to considerable variation due
to conditions under which the lamp is used; under many conditions, the
ozone output may be only a fraction of the specified figure.
Hg - LAMP CONTAINS
MERCURY, manage in
accord with disposal
laws, see:
www.lamprecycle.org |
|
|
Ster-L-Ray�
is a
registered trademark of the
Atlantic Ultraviolet
Corp. |
|
|
|